Gold-in-a-Box™

Gold-in-a-Box is an easy-to-use kit for preparing highly reactive gold conjugates. The Gold-in-a-Box kit enables users to quickly determine (typically in less than one hour) the optimal colloidal-gold binding conditions for attaching soluble proteins, and the Fc portion of purified monoclonal and polyclonal antibodies. The resulting gold particles are highly active and greatly increase the sensitivity of lateral-flow tests. A treated ribbon to produce an optimized gold-conjugate pad is available separately. Customized components are available upon request.

The Gold-in-a-Box kit kit helps you determine the ideal iso-electric point of the coating antibody for optimal binding to the proprietary BioAssay Works gold sols.

The example pictured on the right demonstrates microwell-ELISA-like sensitivity on a rapid, lateral-flow platform. Pictured is an E. coli 0157:H7 assay that achieves an impressive 103 level of sensitivity. Traditional rapid assays have a detection limit of 1-5 pg/ml.

We have demonstrated that our patented C-FLAT® assay platform will permit detection levels of 50 to 250 pg/ml.

gold sol

Pictured at right is the titrated gold sol and the evaluation antibody. The test demonstrates the BioAssay Works buffer determining optimal-coating conditions for antibody or protein.

As seen in the photo, the combination of the gold sol, the buffers and the addition of the antibody of interest produces a reaction indicating the isoelectric point of the antibody or protein of interest.

titrated gold sol

gold test kit

Lateral-flow chromatographic and flow-through tests offer fast detection of critical components for use in point-of-care testing. The key to flow-through tests is the ability to covalently attach antibodies to intensely colored, nanometer particles.

Gold sols that bind ligands through a sulfur bond have proved highly successful for this application. For optimal binding of the antibody or protein while retaining a high degree of specific activity, the pH of the gold sol must be adjusted to slightly above the iso-electric point of the coating antibody or protein.

This is done through a series of pH titrations with the provided buffers. Varying amounts of buffers A and B, and varying amounts of buffers C and D are added to the gold to create a pH 5-11 range. Next, antibody or protein is added, and after 30 minutes the reaction is stopped.


Product Code
Description
QTY
Size
OD
NGIB01-B018
Gold-in-a-Box™ conjugation kit
(9ml 20nm + 9ml 40nm gold, + reagents)
1 Kit
1x9ml 20nm & 1x9ml 40nm
15

NGIB02-B018

Gold-in-a-Box™ conjugation kit
(2 x 9ml 40nm gold, + reagents)

1 Kit

2x9ml 40nm

15

NGIB03-B018

Gold-in-a-Box™ conjugation kit
(2 x 9ml 20nm gold, + reagents)

1 Kit

2x9ml 20nm

15

NGIB01-B044

Gold-in-a-Box™ conjugation kit
(1 x 44ml 20nm gold, + reagents)

1 Kit

1x44 ml 20nm

15

NGIB02-B044

Gold-in-a-Box™ conjugation kit
(1 x 44ml 40nm gold, + reagents)

1 Kit

1x44ml 40nm

15

NGIB01-B100

Gold-in-a-Box™ conjugation kit
(choose 100ml of 20nm, or 100ml of 40nm gold, + reagents)

1 Kit

1x100ml

15



Kit Components for NGIB01-B018
(components for B044 size and B100 sizes are proportionally larger)
  • Naked Gold Sol 40 nm - 9.0 ml (cap with black ring)
  • Naked Gold Sol 20 nm - 9.0 ml (cap with red ring)
  • Buffer Solution A - 1.0 ml (cap with black dot)
  • Buffer Solution B - 1.0 ml (cap with green dot)
  • Buffer Solution C - 1.0 ml (cap with blue dot)
  • Buffer Solution D - 1.0 ml (cap with red dot)
  • BSA Blocking Stabilizer Solution - 2.0 ml (clear cap)
  • Gold Drying Buffer – 2 ml (cap with purple dot)

Materials required but not provided: Clean glass or polystyrene test tubes (12 x 75 mm); pipettes and tips



INSTRUCTIONS

Sample Preparation:
The antibodies or proteins used with this kit must be at a concentration of 1 mg/ml or greater and should be in a 0.5 X PBS buffer solution. If they are not in a 0.5 X PBS buffer solution, then dialyze the antibody or protein against 0.5 X PBS. Proteins at a concentration of 2 mg/ml or greater should be in 1 X PBS.

Generic Procedure, Gold in a Box:
Note: Use aseptic technique when handling the gold sol.

1. Shake or swirl gold to resuspend any settled gold. Place 0.5 ml Naked Gold sol into ten (10) clean individual test tubes.
2. Label each tube with the pH value (or, 1 through 10) from the provided pH charts.
3. Use the pH charts to add varying amounts of buffer in microliters to each test tube. Shake to mix.
4. Place each tube on a low speed vortexer and add antibody solution (See Sample Preparation Section). Mix thoroughly (about 2 to 3 seconds).

Ideally, for the 40 nm gold, 7 µl of a 2 mg/ml solution of antibody or protein is optimal. For the 20 nm gold, ideally, 14 ul of a 2 mg/ml solution of antibody or protein is optimal.

Note: The saturation point for 40 nm gold is typically near 30 mcg of antibody per ml of gold. The saturation point for 20 nm gold is about 60 to 70 mcg of antibody per ml of gold.

5. A deepening purple color and/or black precipitate on some tubes indicates that the antibody or protein is below its iso-electric point, leading to cross-linking of individual gold sols. Cross-linked sols cannot be used in immunological assays and should be discarded. Deep purple sols are usually mostly inactive as well. Only tubes with a slight purple color or no change in color are useful for immunological assays.
6. Allow the reaction to continue for a total of 30 minutes.

Note: See section below on “Stability of Gold Conjugates”.

7. Stop the reaction by the addition of 50 µl of Blocking Stabilizer Solution.

Note: In some conjugates that result in non-specific reactivity, it is often best to allow the blocker to react for an additional 16 hours at room temperature.

Stability of Gold Conjugates, Gold in a Box:

Gold particles completely coated with protein take on the properties of the coating proteins and become very stable in solutions of high ionic strength. An excellent way to test the effectiveness of the conjugation reaction is to combine 10 µl of coated gold sol (prior to the addition of the BSA blocking solution) with 10 µl of 1 M NaCl. Sols with incomplete coating will fall out of solution (turn black), while completely coated sols will remain stable (red).

Testing of BSA Blocked Gold Conjugates:

Conjugate is now ready for use in a rapid assay at nominal usage of 5-15 µl per assay. Tubes that have a slight color change and ones with no color change should be assayed for optimal activity. Tubes with the best activity are usually a good indicator of the approximate iso-electric point of the coated antibody or protein.

In order to effectively dry down the gold, add 0.1 ml of Gold Drying Buffer for every 1.0 ml of conjugate. Mix thoroughly. Apply gradually and evenly to either glass fiber or polyester ribbon.

Place polyester ribbon in a vented 37° C oven or incubator for four (4) hours to dry thoroughly. Glass fiber ribbon should be left in the incubator overnight.

The following alternative drying procedure is for polyester ribbon only:
If a vented incubator is not available, use a hairdryer set to deliver 30° C heat at a ten (10) inch distance from the ribbon surface. Usually, three (3) or four (4) minutes in a wave-motion will suffice to thoroughly dry the ribbon.

Store all dried ribbons in a glass tightly sealable container containing ample desiccants (granular or pouch-form).

Note: This generic procedure may be modified or scaled as needed. When developing a new assay, it is important to determine the optimal amount of ligand to add to the gold particles. Once the tubes have been assayed, it is useful to further optimize binding by both decreasing or increasing the amount of antibody added to each tube. Often, a 20% increase or decrease in antibody or protein added is sufficient to yield an optimal coating procedure. A few cases require a 40% or more increase or decrease in coating antibody or protein.

Discussion, Gold in a Box:
     A sensitive, lateral-flow assay requires that all of the antibody or protein that is added to the gold sol be irreversibly bound to the beads. Any free antibody or protein serves to short-circuit the assay. This behavior ultimately sets the sensitivity limits of an assay.
     
Nano-gold particles remain in solution because they repel each other due to a significant negative charge. This means that proteins bind to gold particles through both ion-exchange attraction and covalent bonding of protein thiols (-SH) with surface gold. The challenge for preparing stable gold conjugates in this “Gold-in-a-Box” format depends upon one's ability to manage the binding of antibody or proteins at or near their iso-electric point. In a few cases, the titration of the pH may need to be fine tuned.
     
The antibodies or proteins in the sample must display a suitable number of surface thiols (-SH). Proteins with no surface thiol groups bind exchangeably with gold particles through ion-exchange interactions. Such proteins do not form stable gold sols that are suitable for flowing chromatographic assays. Equally problematic are protein preparations where surface thiols have been capped or protected by reaction with N-ethyl maleimide or iodoacetic acid.

Application of Gold conjugates, Gold-in-a-Box:
Stabilized gold conjugates made from concentrated sols are ready for use in lateral-flow and flow-through assays without additional optimizations. Typically, 5-15 µl gold conjugate per test will give optimally sensitive assays. The gold conjugate is excellent for use in a variety of gold amplified assay procedures. This includes BioAssay Works' patented, ultra-sensitive C-FLAT technology. Researchers interested in evaluating this technology may contact BioAssay Works for a research use license with no fee.

pH Chart for Optimal coating at a pH of  5-11 (per 0.5 ml of gold)

Tube # pH Buffer A Buffer B
1 5.4 9 µl 1 µl
2 6.6 8 µl 2 µl
3 7.3 6 µl 4 µl
4 7.8 4 µl 6 µl
5 8.2 2 µl 8 µl
Tube # pH Buffer A Buffer B
6 8.4 10 µl 0 µl
7 8.8 8 µl 2 µl
8 9.2 6 µl 4 µl
9 9.6 4 µl 6 µl
10 10.1 2 µl 8 µl

Note: All buffers and the BSA stabilizer contain less than 0.1 % of sodium azide. Sodium azide is very toxic if ingested or inhaled. Avoid contact with skin, eyes, or clothing. Wear eye or face protection when h andling. If skin or eye contact occurs, wash with copious amounts of water. If ingested or inhaled, contact a physician immediatley. Sodium azide yields toxic hydrazoic acid under acidic conditions. Dilute azide-containing compounds in running water before discarding to avoid accumulation of potential explosive deposits in lead or copper plumbing.


BioAssay Works is a registered trademark of BioAssay Works, LLC. The BioAssay Works logo is also a registered trademark. All text, graphics, product names, and interactive media on this website are protected by copyright and may not be copied in any medium without the express written permission of the founders of BioAssay Works, LLC.